RS-485(Modbus RTU Protocol) Distributed Remote I/O Module with16-ch Digital Input(DI)
RS-485(Modbus RTU) Data Acquisition Module
Product Introduction (RS-6000M Series)
RS-6000M RS485-based data acquisition and control modules provide I/O, data acquisitions, and networking in one module to build a cost effective, distributed monitoring and control solution for a wide variety of applications. With RS485-based technology, RS-6000M series modules build up a cost-effective DA&C system for building automation, environmental monitoring, and manufacturing applications. Modbus has become a standard communication, and is now the most commonly available means of connecting industrial. This makes the RS-6000M series perfect for integration with HMI, SCADA, PLC and other software systems.
Feature and Benefits:
- 32 bits & 120M high speed CPU, the real time embedded OS.
- DI can read more than 600 times/second.
- Optocoupler isolation: Digital Input and Output(DI & DO),
- RS-485: Separate isolation
- Power or dual power(Analogue Modules): Independent isolation
- Built-in Surge protection: 15KV
- Analogue input(AI): Magnetic coupling isolation and protection.
- The input voltage can be positive and negative, each channel has built-in TVS and ESD protection.
- The measuring range can be shifted by software.
- The single end and differential can be shifted by software. Single end can reach 16 channels.
- The ID and baud rate can be adjusted by rotary button directly.
- Enclosure: shielded metal
- The differential sampling frequency can reach 50Hz/channel
Hardware Specification:
|
System |
|||
|
CPU |
32-bit 120MIPS CPU |
||
|
Operation System |
Real-Time |
||
|
Watchdog |
Yes |
||
|
Communication |
RS-6000M |
CAN-6000T |
NET-6000M |
|
|
RS485 |
CAN |
Ethernet 10/100 Base-TX |
|
LED Display |
|||
|
Power Indicator |
Red |
||
|
Run Indicator |
Green |
||
|
Error Indicator |
Red |
||
|
Link Indicator |
Green |
||
|
Act Indicator |
Yellow |
||
|
Mechanical |
|||
|
Dimensions (W x H x D)(mm) |
140*110*40 |
||
|
Installation |
DIN-Rail mounting |
||
|
Environment |
|||
|
Operating Temperature |
-20℃~+70℃ |
||
|
Storage Temperature |
-30℃~+80℃ |
||
|
Power Requirements |
|||
|
Power Input |
+9V~30V DC |
||
|
Power Consumption |
<3W |
||
I/O Specification:
|
Model |
RS-6011M |
RS-6012M |
RS-6013M |
||
|
Digital Input |
|||||
|
Input Channels |
16 |
|
8 |
||
|
Input Type |
Dry Contact |
Wet Contact |
|
Dry Contact |
Wet Contact |
|
On Voltage Level |
Close to GND |
0V~1V DC |
|
Close to GND |
0V~1V DC |
|
Off Voltage Level |
Open |
3V~50V DC |
|
Open |
3V~50V DC |
|
Overvoltage Protection |
+70V |
|
+70V |
||
|
Isolation |
3750Vrms |
|
3750Vrms |
||
|
Digital Output |
|||||
|
Output Channels |
|
16 |
8 |
||
|
Output Type |
|
Sink, Open Collector(NPN) |
Sink, Open Collector(NPN) |
||
|
Load Voltage |
|
Max 50V DC |
Max 50V DC |
||
|
Max Load Current |
|
500mA/channel |
500mA/channel |
||
|
Isolation |
|
3750Vrms |
3750Vrms |
||
Ordering Information:
1.2 Odering Information (RS-6000M RS485 Modbus RTU Series)
|
Model |
Description |
|
Digital I/O |
|
|
RS-6011M |
RS485 Remote I/O Module with16-ch DI |
|
RS-6012M |
RS485 Remote I/O Module with16-ch DO |
|
RS-6013M |
RS485 Remote I/O Module with 8-ch DI and 8-ch DO |
|
Relay Output |
|
|
RS-6014M |
RS485 Remote I/O Module with 5-ch Relay(Form A) |
|
RS-6015M |
RS485 Remote I/O Module with 5-ch Relay(3-ch Form A, 2-ch Form C) |
|
Analog Input |
|
|
RS-6021M |
RS485 Remote I/O Module with 12bit 16-ch Single End AI or 8-ch differential AI |
|
RS-6022M |
RS485 Remote I/O Module with 16bit 16-ch Single End AI or 8-ch differential AI |
|
Analog Output |
|
|
RS-6031M |
RS485 Remote I/O Module with 12bit 4-ch AO |
|
RS-6032M |
RS485 Remote I/O Module with 16bit 4-ch AO |
|
RTD |
|
|
RS-6041M |
RS485 Remote I/O Module with 5-ch RTD |
|
Thermocouple |
|
|
RS-6042M |
RS485 Remote I/O Module with 5-ch TC |
|
Mixed |
|
|
RS-6088 |
RS485 Remote I/O Module with 16bit 8-ch Single End AI or 4-ch differential AI, 12bit 4-ch AO, 2-ch DI, 2-ch DO |